Water Sci Technol ; 84(5): 1270-1279, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34534122

RESUMO

Peracetic acid (PAA) stands out as a safe and environmental-friendly oxidant and disinfectant which has been effectively used in wastewater treatment. Chemical oxygen demand (COD) is a very popular analysis in wastewater treatment; however, the interference of residual PAA on the COD measurement is still unknown. In this context, this study investigated the implications of applying the COD analysis in PAA-based treatment. Each 1 mg·L-1 of PAA increased the COD concentration around 13.5 mg O2·L-1. Residual PAA and hydrogen peroxide (H2O2) were efficiently neutralized by sodium metabisulfite (SMBS) at the optimal SMBS/PAA ratio of 10.2:1 in a wide pH range (5 to 9). The effect of PAA addition on the COD concentration was evaluated in different water matrices (potassium hydrogen phthalate and wastewater solutions). The COD results with the SMBS addition at optimal SMBS/PAA ratio were lower than the ones without it. It may happen due to the neutralization of residual H2O2/PAA and the complexity of the water matrices which can interfere in the COD results. This study discussed the impact of the residual H2O2/PAA neutralization before the COD analysis, and this investigation can be used as a practical guideline for the correct COD measurement in PAA-based treatment.


Assuntos
Ácido Peracético , Purificação da Água , Análise da Demanda Biológica de Oxigênio , Desinfecção , Peróxido de Hidrogênio/análise